Critical Design and Characterization Methodology for a Homemade Three-Axis Fluxgate Magnetometer Measuring Ultra-Low Magnetic Fields
| dc.contributor.author | Can, Hava | |
| dc.contributor.author | Kutlu, Fatma Nur Celik | |
| dc.contributor.author | Svec, Peter | |
| dc.contributor.author | Skorvanek, Ivan | |
| dc.contributor.author | Sozeri, Huseyin | |
| dc.contributor.author | Dogan, Cetin | |
| dc.contributor.author | Topal, Ugur | |
| dc.date.accessioned | 2025-10-29T11:08:42Z | |
| dc.date.issued | 2025 | |
| dc.department | Gebze Teknik Üniversitesi | |
| dc.description.abstract | This paper presents the design, fabrication, calibration, and comprehensive characterization of a homemade tri-axial fluxgate magnetometer. The magnetometer, utilizing a ring core configuration, was developed to measure ultra-low magnetic fields with high sensitivity and stability. Critical stages from material selection to sensor geometry optimization are discussed in detail. A series of critical characterization processes were conducted, including zero-field voltage determination, scale factor calculation, resolution measurement, noise analysis, bias assessment, cross-field effect evaluation, temperature dependency, and bandwidth determination. The sensor demonstrated a minimum detectable magnetic field resolution of 2.2 nT with a noise level of 1.1 nT/root Hz at 1 Hz. Temperature dependency tests revealed minimal impact on sensor output with a maximum shift of 120 nT in the range of 60 degrees C, which was effectively compensated through calibration to less than 5 nT. Additionally, the paper introduces a model function in matrix form to relate the magnetometer's output voltage to the measured magnetic field, incorporating temperature dependency and cross-field effects. This work highlights the importance of meticulous calibration and optimization in developing fluxgate magnetometers suitable for various applications, from space exploration to biomedical diagnostics. | |
| dc.description.sponsorship | TUBITAK (The Scientific and Technological Research Council of Turkey) | |
| dc.description.sponsorship | Slovak Academy of Sciences [218M647, 123N773] | |
| dc.description.sponsorship | TUBITAK | |
| dc.description.sponsorship | This research was funded by TUBITAK (The Scientific and Technological Research Council of Turkey) and Slovak Academy of Sciences, with project numbers of 218M647 and 123N773. The former one was supported through 1003 programme of TUBITAK. The latter is a joint project between the Slovak Academy of Sciences and TUEB & Idot;TAK, under the acronym NOMAGRAD. | |
| dc.identifier.doi | 10.3390/s25133971 | |
| dc.identifier.issn | 1424-8220 | |
| dc.identifier.issue | 13 | |
| dc.identifier.pmid | 40648225 | |
| dc.identifier.scopus | 2-s2.0-105010319779 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.uri | https://doi.org/10.3390/s25133971 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/5478 | |
| dc.identifier.volume | 25 | |
| dc.identifier.wos | WOS:001527533100001 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Mdpi | |
| dc.relation.ispartof | Sensors | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | fluxgate magnetometer | |
| dc.subject | ultra-low-field magnetic sensors | |
| dc.subject | soft magnetic alloys | |
| dc.subject | measurement techniques | |
| dc.subject | calibration | |
| dc.title | Critical Design and Characterization Methodology for a Homemade Three-Axis Fluxgate Magnetometer Measuring Ultra-Low Magnetic Fields | |
| dc.type | Article |








