Pyrophosphate Sensor Based on Principal Component Analysis of Conjugated Polyelectrolyte Fluorescence

dc.contributor.authorYang, Jie
dc.contributor.authorAcharya, Rajendra
dc.contributor.authorZhu, Xuzhi
dc.contributor.authorKose, Muhammet E.
dc.contributor.authorSchanze, Kirk S.
dc.date.accessioned2025-10-29T11:20:30Z
dc.date.issued2016
dc.departmentFakülteler, Temel Bilimler Fakültesi, Kimya Bölümü
dc.description.abstractThe pyrophosphate anion (PPi) plays an important role in biochemical processes. Therefore, a simple but reliable analytical technique is essential for selective detection of PPi in biochemical systems. Here, we present a principal component analysis (PCA) method for analytical determination of PPi concentration using a fluorescent conjugated polyelectrolyte (CPE) combined with a polyamine modifier. The CPE has anionic side chains and dissolves molecularly in water, as indicated by its structured fluorescence emission spectrum. However, addition of tris(3-aminoethyl) amine (tetraamine or N4) quenches the CPE fluorescence emission. Tetraamine, which is a polycation at neutral pH, binds multiple anionic CPE chains, leading to aggregate formation, resulting in aggregation-induced fluorescence quenching. Addition of PPi to the polymer-amine aggregate reverses the process, resulting in fluorescence recovery. The relatively higher concentration of PPi compared to that of the polymer allows it to effectively compete to bind the amine, thus releasing molecularly dissolved polymer chains. Fluorescence correlation spectroscopy of the P1/N4 complex and of P1/N4/PPi confirms the change in size of the CPE aggregates that occurs upon reversible aggregation. Application of PCA to the fluorescence emission data set of standard samples yields two principal components, which are used to create a predictive model for PPi analysis. The PCA method is able to directly determine the concentration of PPi with approximately 95% accuracy within the concentration range from 100 mu M to 3 mM, without the need for a reference state as is typically needed for ratiometric fluorescence assays.
dc.description.sponsorshipProminski Endowment at the University of Florida
dc.description.sponsorshipSupport from the Prominski Endowment at the University of Florida is acknowledged.
dc.identifier.doi10.1021/acsomega.6b00189
dc.identifier.endpage655
dc.identifier.issn2470-1343
dc.identifier.issue4
dc.identifier.orcid0000-0003-3153-7436
dc.identifier.pmid31457154
dc.identifier.scopus2-s2.0-85028940455
dc.identifier.scopusqualityQ1
dc.identifier.startpage648
dc.identifier.urihttps://doi.org/10.1021/acsomega.6b00189
dc.identifier.urihttps://hdl.handle.net/20.500.14854/8613
dc.identifier.volume1
dc.identifier.wosWOS:000392717300015
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherAmer Chemical Soc
dc.relation.ispartofAcs Omega
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectCorrelation Spectroscopy
dc.subjectAqueous-Solution
dc.subjectAggregation
dc.subjectSpectra
dc.subjectCadmium
dc.subjectPhotophysics
dc.subjectAnion
dc.subjectWater
dc.subjectPpi
dc.subjectTemperature
dc.titlePyrophosphate Sensor Based on Principal Component Analysis of Conjugated Polyelectrolyte Fluorescence
dc.typeArticle

Dosyalar