Fouling characteristics of microfiltration membranes during the filtration of jet loop membrane bioreactor (JLMBR) activated sludge

dc.contributor.authorImer-Koseoglu, Derya Yuksel
dc.contributor.authorKaragündüz, Ahmet
dc.contributor.authorKeskinler, Bülent
dc.date.accessioned2025-10-29T11:08:03Z
dc.date.issued2011
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.descriptionInternational Workshop on Urbanisation, Land Use, Land Degradation and Environment -- SEP 28-OCT 01, 2009 -- Denizli, TURKEY
dc.description.abstractThe main objective of this study was to characterize the activated sludge of jet loop membrane bioreactor (JLMBR) in order to determine its effects on the membrane biofouling. The sludge characteristics were evaluated in terms of MLSS (mixed liquor suspended solid), EPS (extracellular polymeric substance), SMP (soluble microbial product), relative hydrophicity (RH) and viscosity. The membrane filtration tests were performed at a cross-flow microfiltration system by using cellulose acetate (CA) and cellulose nitrate (CN) filters with 0.2 and 0.45 mu m of pore sizes. The jet loop bioreactor was operated at a batch mode for 36 d with an organic load of 3 kg COD m(-3)d(-1). The COD treatment efficiency was achieved at 95%. It was found that the sludge properties changed with MLSS concentration. The viscosity of sludge increased and the RH of sludge decreased with increase in MLSS concentration. The EPS concentration of the sludge was much higher than SMP concentration. The carbohydrate contents of EPS and SMP were higher than the protein contents. The flux decline models and the resistance analysis were used to investigate the biofouling mechanism. In the resistance analysis, it was found that the pore blocking resistance (R-p) of CA membrane with pore size of 0.45 mu m (CA045) was higher than the cake layer resistance (R-c), (3.56 and 1.02 x 10(12) m(-1)). R c was more higher than R-p for the other membranes. R-p of membranes were found to be 33.6%, 77.1%, 23.4% and 21.9% of the total resistances (R-t) for CA02, CA045, CN02 and CN045, respectively. It was concluded that the high EPS content in JLMBR was the main fouling parameter for membranes. It was also found that the affinity of membrane types against EPS varied.
dc.description.sponsorshipTUBITAK, the Scientific and Technological Research Council of Turkey [108Y129]
dc.description.sponsorshipThis study was financially supported by the TUBITAK, the Scientific and Technological Research Council of Turkey (Project No: 108Y129).
dc.identifier.doi10.5004/dwt.2011.2121
dc.identifier.endpage130
dc.identifier.issn1944-3994
dc.identifier.issn1944-3986
dc.identifier.issue1-3
dc.identifier.orcid0000-0003-3023-4556
dc.identifier.orcid0000-0002-8406-0718
dc.identifier.scopus2-s2.0-79952215603
dc.identifier.scopusqualityQ3
dc.identifier.startpage124
dc.identifier.urihttps://doi.org/10.5004/dwt.2011.2121
dc.identifier.urihttps://hdl.handle.net/20.500.14854/5183
dc.identifier.volume26
dc.identifier.wosWOS:000287816400018
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTaylor & Francis Inc
dc.relation.ispartofDesalination and Water Treatment
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectJet loop membrane bioreactor
dc.subjectMembrane biofouling
dc.subjectCrossflow microfiltration
dc.titleFouling characteristics of microfiltration membranes during the filtration of jet loop membrane bioreactor (JLMBR) activated sludge
dc.typeConference Object

Dosyalar