Comparison of Aflatoxin B1 Measurement Efficiencies of 5 MHz QCM and 120 MHz Love Wave Sensors

dc.contributor.authorPirincci, Serife Seyda
dc.contributor.authorErtekin, Ozlem
dc.contributor.authorOzturk, Zafer Ziya
dc.contributor.authorOzturk, Selma
dc.date.accessioned2025-10-29T11:37:31Z
dc.date.issued2018
dc.departmentFakülteler, Temel Bilimler Fakültesi, Fizik Bölümü
dc.description4th International Conference on Sensors and Electronic Instrumentation Advances (SEIA) -- SEP 19-21, 2018 -- Amsterdam, NETHERLANDS
dc.description.abstractAflatoxin B1 (AFB1), which is a prominent fungal secondary metabolite due to its hepatoxic and carcinogenic properties, is monitored due to its negative effects on health. However, since these observations are carried out with laboratory installed devices, the increase of contamination after measurement can not be observed and therefore, the contaminating products can be presented to the user. Biosensors are seen as strong candidates in order to make the monitoring more efficient and effective. There are many biosensor studies for detection of aflatoxins with biosensors, but they are not yet used in routine biosensor monitoring. The reason for this is argued as the sensitivity of these devices and measurement precision can not compete with the built-in devices. Therefore, stable and precise measurement methods and technologies need to be developed. In this study, Love wave biosensor was used for the first time for measurement of free Aflatoksin B1 and the results obtained with this study was compared with the results of 5 MHz QCM measurements. For both of these studies the same measurement method was applied. As a result of the study, it was observed that 250 ppt can be determined with a 120 MHz Love wave sensor while 5 MHz QCM can measure 1250 ppt AFB1 at a minimum.
dc.description.sponsorshipInt Frequency Sensor Assoc,Asian Soc Appl Math & Engn,F2D Ltd,My Dear Drone,MDPI, Sensors Journal,MDPI, Chemosensors Journal,MDPI, Instruments Journal,MDPI, Micromachines Journal
dc.description.sponsorshipTUBITAK [110G139]
dc.description.sponsorshipTUBITAK Marmara Research Center project [5133101]
dc.description.sponsorshipThis work was supported by TUBITAK project number 110G139 and TUBITAK Marmara Research Center project number 5133101.
dc.identifier.endpage101
dc.identifier.isbn978-84-09-04910-3
dc.identifier.issn#DEĞER!
dc.identifier.startpage100
dc.identifier.urihttps://hdl.handle.net/20.500.14854/13866
dc.identifier.wosWOS:000567303500027
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherInt Frequency Sensor Assoc-Ifsa
dc.relation.ispartofSensors and Electronic Instrumentation Advances (Seia'2018)
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectAflatoxin B1
dc.subjectQCM
dc.subjectLove wave
dc.subjectBiosensor
dc.titleComparison of Aflatoxin B1 Measurement Efficiencies of 5 MHz QCM and 120 MHz Love Wave Sensors
dc.typeConference Object