Strain-induced magnetic anisotropies in epitaxial CrO2 thin films probed by FMR technique

dc.contributor.authorRameev, B. Z.
dc.contributor.authorGupta, A.
dc.contributor.authorYildiz, F.
dc.contributor.authorTagirov, L. R.
dc.contributor.authorAktas, B.
dc.date.accessioned2025-10-29T11:26:27Z
dc.date.issued2006
dc.departmentFakülteler, Temel Bilimler Fakültesi, Fizik Bölümü
dc.description.abstractEpitaxial CrO2 thin films were grown onto TiO2 (100) single-crystalline substrates by chemical vapour deposition (CVD) process with use of the solid precursor CrO3. The CrO2 films with thickness of 27 and 65nm were deposited onto TiO2 substrates pre-etched in the diluted HF. The magnetic properties of the epitaxial chromium-dioxide films have been probed by the ferromagnetic resonance (FMR) technique. Analysis of the FMR spectra shows that the magnetic behaviour of the CrO2 films results from a competition between magnetocrystalline and strain anisotropies. The thin films are heavily strained due to lattice mismatch of CrO2 epitaxial film with the TiO2 single-crystalline substrate. For the thinnest film (27 nm) the stress anisotropy dominates, and the magnetic easy axis switches from the c direction to the b direction of the rutile structure. Unusual angular dependence of the resonance signal and multiple FMR modes are observed for the film with the thickness of 65 nm, where a partial strain relaxation results in appearance of two magnetic phases with mutually perpendicular easy axes along the c and b directions. (C) 2005 Elsevier B.V. All rights reserved.
dc.description.sponsorshipDPT (State Planning Organization of Turkey) [2003K 120530]
dc.description.sponsorshipTUBITAK [104T176]
dc.description.sponsorshipThis work was supported by DPT (State Planning Organization of Turkey) through the grant No. 2003K 120530 and by TUBITAK through the grant No. 104T176.
dc.identifier.doi10.1016/j.jmmm.2005.10.207
dc.identifier.endpageE529
dc.identifier.issn0304-8853
dc.identifier.issue1
dc.identifier.orcid0000-0003-0828-8312
dc.identifier.orcid0000-0002-1785-7209
dc.identifier.orcid0000-0002-1549-7940
dc.identifier.scopus2-s2.0-33644681604
dc.identifier.scopusqualityQ2
dc.identifier.startpageE526
dc.identifier.urihttps://doi.org/10.1016/j.jmmm.2005.10.207
dc.identifier.urihttps://hdl.handle.net/20.500.14854/10285
dc.identifier.volume300
dc.identifier.wosWOS:000208212300137
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Bv
dc.relation.ispartofJournal of Magnetism and Magnetic Materials
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectThin films
dc.subjectHalf-metallic materials
dc.subjectMagnetic anisotropy
dc.subjectFerromagnetic resonance
dc.titleStrain-induced magnetic anisotropies in epitaxial CrO2 thin films probed by FMR technique
dc.typeArticle

Dosyalar