Experimental study on an air-based photovoltaic-thermal (PV-T) system with a converging thermal collector geometry: A comparative performance analysis

dc.contributor.authorVajedi, Hadi
dc.contributor.authorDehghan, Maziar
dc.contributor.authorAminy, Mohammad
dc.contributor.authorPourrajabian, Abolfazl
dc.contributor.authorIlis, Gamze Gediz
dc.date.accessioned2025-10-29T11:23:00Z
dc.date.issued2022
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractAn air-based photovoltaic-thermal (PV-T) system with a converging collector (i.e. a channel with a decreasing hydraulic diameter), to the best of authors' knowledge for the first time, has been experimentally studied against a PV-T counterpart with the conventional thermal collector geometry (i.e. with fixed hydraulic diameter) as well as a PV module with no thermal management system. An iterative method for the calculation of the convective heat transfer coefficient (h(d)) introduced in the study revealed that h(d) for a conventional thermal collector can be easily increased up to 38 % using the idea of the converging collector with no need for any extra energy or cost. According to the measurements, this enhancement results in an increase in the net overall efficiency of the PV-T system by 12 % on average compared to a PV-T system with a conventional thermal collector. Meanwhile, the converging thermal collector results in an almost uniform temperature distribution for the PV, confirming the idea of the uniform cooling in air-based PV-T systems is possible, which has not been previously reported.
dc.description.sponsorshipIran National Science Foundation INSF [98026934]
dc.description.sponsorshipThis work was supported by the Iran National Science Foundation INSF (grant number 98026934).
dc.identifier.doi10.1016/j.seta.2022.102153
dc.identifier.issn2213-1388
dc.identifier.issn2213-1396
dc.identifier.orcid0000-0001-8366-5427
dc.identifier.orcid0000-0003-2106-6300
dc.identifier.orcid0000-0003-0600-315X
dc.identifier.orcid0000-0002-4205-0685
dc.identifier.scopus2-s2.0-85126579706
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.seta.2022.102153
dc.identifier.urihttps://hdl.handle.net/20.500.14854/9229
dc.identifier.volume52
dc.identifier.wosWOS:000789644200002
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofSustainable Energy Technologies and Assessments
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectAir -based photovoltaic-thermal (PV -T) system
dc.subjectConverging thermal collector
dc.subjectUniform cooling
dc.subjectConvective heat transfer coefficient
dc.subjectThermal and electrical efficiencies
dc.titleExperimental study on an air-based photovoltaic-thermal (PV-T) system with a converging thermal collector geometry: A comparative performance analysis
dc.typeArticle

Dosyalar