dc.description.abstractThe aim of this study is to investigate the membrane fouling in a thermophilic membrane bioreactor (TMBR) operated different sludge retention times (SRTs). For this purpose, TMBR was operated at four different SRTs (10, 30, 60 and 100 days). Specific cake resistance (alpha), cake resistance, gel resistance, total resistance, MFI (modified fouling index) and FDR (flux decrease ratio) were calculated for all SRTs. It was observed that flux in the membrane increases with rising SRT although the sludge concentrations in the TMBR increased. The steady state flux was found to be 31.78; 34.70; 39.60 and 43.70 LMH (Liter/m(2)/h) for the SRTs of 10, 30, 60 and 100 days respectively. The concentrations of extracellular polymeric substance (EPS) and soluble microbial product (SMP) decreased with increasing SRT. The membrane fouling rate was higher at shorter SRT and the highest fouling rate appeared at an SRT of 10 d. Both the sludge cake layer and gel layer had contribution to the fouling resistance, but the gel layer resistance value was dominant in all SRTs.
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [110Y134]
dc.description.sponsorshipThis study was financially supported by the Scientific and Technological Research Council of Turkey (TUBITAK) with the project number 110Y134.
dc.identifier.doi10.12989/mwt.2018.9.4.245
dc.identifier.endpage253
dc.identifier.issn2005-8624
dc.identifier.issn2092-7037
dc.identifier.issue4
dc.identifier.orcid0000-0002-6221-8836
dc.identifier.scopus2-s2.0-85050780129
dc.identifier.scopusqualityQ3
dc.identifier.startpage245
dc.identifier.urihttps://doi.org/10.12989/mwt.2018.9.4.245
dc.identifier.urihttps://hdl.handle.net/20.500.14854/6304
dc.identifier.volume9
dc.identifier.wosWOS:000443915600005
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTechno-Press
dc.relation.ispartofMembrane Water Treatment
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectEPS
dc.subjectflux
dc.subjectfouling
dc.subjectMBR
dc.subjectresistance
dc.subjectSMP
dc.subjectSRT
dc.subjectthermophilic
dc.titleImpacts of sludge retention time on membrane fouling in thermophilic MBR
dc.typeArticle