Arsenite removal from groundwater in a batch electrocoagulation process: Optimization through response surface methodology
| dc.contributor.author | Demirbas, Erhan | |
| dc.contributor.author | Kobya, Mehmet | |
| dc.contributor.author | Oncel, Mehmet Salim | |
| dc.contributor.author | Sik, Emrah | |
| dc.contributor.author | Goren, Aysegul Yagmur | |
| dc.date.accessioned | 2025-10-29T11:17:17Z | |
| dc.date.issued | 2019 | |
| dc.department | Fakülteler, Temel Bilimler Fakültesi, Kimya Bölümü | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | |
| dc.description.abstract | In this study, influences of seven process variables such as initial pH (pH(i)), applied current (i), operating time (t(EC)), initial As(III) concentration (C-o), diameter of Fe ball anode (d(p)), column height in the electrocoagulation (EC) reactor (h) and airflow rate (Q(air)) for removal of As(III) from groundwater by a new air-fed fixed-bed EC reactor were evaluated with a response surface methodology (RSM). The proposed quadratic model fitted very well with the experimental data for the responses. The removal efficiencies and operating costs were determined to be 99% and 0.01 $/m(3) at the optimum operating conditions (a pH(i) of 8.5, 0.05 A, 4.94 min, d(p) of 9.24 mm, h of 7.49 cm, Q(air) of 9.98 L/min for 50 mu g/L). This study clearly showed that the RSM in the EC process was a very suitable method to optimize the operating conditions at the target value of effluent As(III) concentration (10 mu g/L) while keeping the operating cost to minimal and maximize the removal efficiency. | |
| dc.description.sponsorship | TUBITAK [111Y103] | |
| dc.description.sponsorship | The authors would like to thank TUBITAK for the financial support of this work (contract no: 111Y103). | |
| dc.identifier.doi | 10.1080/01496395.2018.1521834 | |
| dc.identifier.endpage | 785 | |
| dc.identifier.issn | 0149-6395 | |
| dc.identifier.issn | 1520-5754 | |
| dc.identifier.issue | 5 | |
| dc.identifier.orcid | 0000-0001-6732-8893 | |
| dc.identifier.orcid | 0000-0003-1114-6059 | |
| dc.identifier.orcid | 0000-0002-5224-2672 | |
| dc.identifier.scopus | 2-s2.0-85054579063 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 775 | |
| dc.identifier.uri | https://doi.org/10.1080/01496395.2018.1521834 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/7993 | |
| dc.identifier.volume | 54 | |
| dc.identifier.wos | WOS:000464574300012 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Taylor & Francis Inc | |
| dc.relation.ispartof | Separation Science and Technology | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | Arsenite removal | |
| dc.subject | groundwater | |
| dc.subject | electrocoagulation | |
| dc.subject | Fe ball anode | |
| dc.subject | optimization | |
| dc.title | Arsenite removal from groundwater in a batch electrocoagulation process: Optimization through response surface methodology | |
| dc.type | Article |








