Removal of arsenic in groundwater from western Anatolia, Turkey using an electrocoagulation reactor with different types of iron anodes

dc.contributor.authorKobya, Mehmet
dc.contributor.authorDolaz, Mustafa
dc.contributor.authorOzaydin-Senol, Burcu
dc.contributor.authorGoren, Aysegul Yagmur
dc.date.accessioned2025-10-29T11:27:36Z
dc.date.issued2022
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractElectrocoagulation (EC) is a significantly efficient method for As removal from waters and received considerable attention recently. In this study, the natural groundwater (GW) samples containing As concentrations of GW-1: 538.8 mu g L-1, GW-2: 1132.1 mu g L-1, and GW-3: 52, 000 mu g L-1 were obtained from different provinces and treated by EC process using different iron anodes (plate, ball, and scrap). To achieve drinking water As standard (10 mu g L-1), the operational time, applied current, and As removal optimization for all anode types were studied. At applied current of 0.025 A, the As removal efficiency, EC time, and operating cost were > 99.9%, 180 min and 0.406 $ m(-3) for ball anodes, > 99.9%, 100 min and 0.0813 $ m(-3) for plate anodes, > 99.9%, 80 min and 0.0815 $ m(-3) for scrap anodes for GW-3, respectively. It was observed that as the As concentration in the GW increased, the EC time and operating cost increased. Overall, it was concluded that Fe scrap anodes are more advantageous than other types of anodes in terms of operating cost in EC reactor for As removal.
dc.identifier.doi10.1016/j.heliyon.2022.e10489
dc.identifier.issn2405-8440
dc.identifier.issue9
dc.identifier.orcid0000-0003-1114-6059
dc.identifier.orcid0000-0002-9684-5555
dc.identifier.pmid36105457
dc.identifier.scopus2-s2.0-85137642218
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.heliyon.2022.e10489
dc.identifier.urihttps://hdl.handle.net/20.500.14854/10823
dc.identifier.volume8
dc.identifier.wosWOS:000860591400018
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherCell Press
dc.relation.ispartofHeliyon
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectArsenic removal
dc.subjectElectrocoagulation
dc.subjectGroundwater
dc.subjectBall anode
dc.subjectScrap anode
dc.subjectPlate anode
dc.titleRemoval of arsenic in groundwater from western Anatolia, Turkey using an electrocoagulation reactor with different types of iron anodes
dc.typeArticle

Dosyalar