Label-Free QCM Immunosensor for the Detection of Ochratoxin A
| dc.contributor.author | Pirincci, Serife Seyda | |
| dc.contributor.author | Ertekin, Ozlem | |
| dc.contributor.author | Laguna, Duygu Ercan | |
| dc.contributor.author | Ozen, Fehime Seyma | |
| dc.contributor.author | Ozturk, Zafer Ziya | |
| dc.contributor.author | Ozturk, Selma | |
| dc.date.accessioned | 2025-10-29T11:08:43Z | |
| dc.date.issued | 2018 | |
| dc.department | Fakülteler, Temel Bilimler Fakültesi, Fizik Bölümü | |
| dc.description.abstract | Ochratoxin A (OTA) is a potent mycotoxin that poses a risk in food and feed moieties and subject to worldwide regulation. Laboratory-based analytical methods are traditionally employed for reliable OTA quantification, but these methods cannot provide rapid and on-site analysis, where biosensors fill this gap. In this study a label-free quartz crystal microbalance (QCM)-based immunosensor for the detection of OTA, which is one of the most important small molecule contaminants, was developed by direct immobilization of OTA to amine-bearing sensor surfaces using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC)/N-Hydroxysuccinimide (NHS) chemistry. The protein-free sensor surface enabled regeneration of sensor surface with 50 mM NaOH and 1% SDS up to 13 times without loss of performance, which would disrupt a protein-containing sensor surface. We developed a QCM immunosensor using the developed sensor surface with a 17.2-200 ng/mL detection range which can be used for on-site detection of feedstuffs. | |
| dc.description.sponsorship | TUBITAK [110G139] | |
| dc.description.sponsorship | TUBITAK Marmara Research Center [5133101] | |
| dc.description.sponsorship | We are grateful to Harun Kocaaga for his technical assistance. This work was supported by TUBITAK project number 110G139 and TUBITAK Marmara Research Center project number 5133101. | |
| dc.identifier.doi | 10.3390/s18041161 | |
| dc.identifier.issn | 1424-8220 | |
| dc.identifier.issue | 4 | |
| dc.identifier.orcid | 0000-0001-5659-5806 | |
| dc.identifier.pmid | 29641432 | |
| dc.identifier.scopus | 2-s2.0-85045325499 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.uri | https://doi.org/10.3390/s18041161 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/5481 | |
| dc.identifier.volume | 18 | |
| dc.identifier.wos | WOS:000435574800233 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Mdpi | |
| dc.relation.ispartof | Sensors | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | OTA | |
| dc.subject | Ochratoxin A | |
| dc.subject | QCM | |
| dc.subject | quartz crystal microbalance | |
| dc.subject | immunobiosensor | |
| dc.subject | regeneration | |
| dc.subject | immobilization | |
| dc.title | Label-Free QCM Immunosensor for the Detection of Ochratoxin A | |
| dc.type | Article |








