A capillary driven microfluidic chip for SERS based hCG detection

dc.contributor.authorAhi, Elcin Ezgi
dc.contributor.authorTorul, Hilal
dc.contributor.authorZengin, Adem
dc.contributor.authorSucularli, Ferah
dc.contributor.authorYildirim, Ender
dc.contributor.authorSelbes, Yesim
dc.contributor.authorSuludere, Zekiye
dc.date.accessioned2025-10-29T11:30:14Z
dc.date.issued2022
dc.departmentFakülteler, İşletme Fakültesi, İşletme Bölümü
dc.departmentFakülteler, Mühendislik Fakültesi, Kimya Mühendisliği Bölümü
dc.description.abstractIn this study, a capillary driven microfluidic chip-based immunoassay was developed for the determination of Human Chorionic Gonadotropin (hCG) protein, which is prohibited by the World Anti-Doping Agency (WADA). Here, we used antibody modified magnetic metal organic framework nanoparticles (MMOFs) as a capture prob in urine sample. MMOF captured hCG was transferred in a capillary driven microfluidic chip consisting of four chambers, and the interaction of MMOF with gold nanorods labelled with 5,5'-Dithiobis-(2-nitrobenzoic acid) (DTNB) as a Raman label was carried out in the capillary driven microfluidic chip. The movement of MMOF through first chamber to the last chamber was achieved with a simple magnet. In the last chamber of capillary driven microfluidic chip, SERS signals of DTNB molecules from the sandwich complex were recorded using a Raman spectrophotometer. The selectivity of the developed method was demonstrated by applying the same procedure for the detection of Human Luteinizing Hormone (hLH), Human Chorionic Gonadotropin Hormone (hGH) and Immunoglobulin G (IgG) protein. The regression coefficient and limit of detection obtained from the standard addition method were found as 0,9985 and 0,61 IU/L, respectively. Furthermore, the conventional ELISA method confirmed that the results obtained by the presented method were acceptable with the similarity of 97.9% in terms of average recovery value, for the detection of hCG in urine samples. The analysis system developed for target proteins will be an alternative technique such as Western Blot used in routine analysis that is expensive and time consuming.
dc.description.sponsorshipGazi University Scientific Research Department (Ankara, Turkey) [02/2019-16]
dc.description.sponsorshipThis study was supported by Gazi University Scientific Research Department (Ankara, Turkey; Project No. 02/2019-16) .
dc.identifier.doi10.1016/j.bios.2021.113660
dc.identifier.issn0956-5663
dc.identifier.issn1873-4235
dc.identifier.orcid0000-0001-9989-6123
dc.identifier.orcid0000-0002-1207-5814
dc.identifier.orcid0000-0002-7969-2243
dc.identifier.pmid34592500
dc.identifier.scopus2-s2.0-85115815285
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.bios.2021.113660
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11464
dc.identifier.volume195
dc.identifier.wosWOS:000705223300006
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Advanced Technology
dc.relation.ispartofBiosensors & Bioelectronics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectHuman chorionic gonadotropin protein
dc.subjectMetal organic framework
dc.subjectCapillary driven microfluidic chip
dc.subjectSurface enhanced Raman spectroscopy
dc.titleA capillary driven microfluidic chip for SERS based hCG detection
dc.typeArticle

Dosyalar