The treatment of greywater from a restaurant by electrosynthesized ferrate (VI) ion
| dc.contributor.author | Barisci, Sibel | |
| dc.contributor.author | Sarkka, Heikki | |
| dc.contributor.author | Sillanpaa, Mika | |
| dc.contributor.author | Dimoglo, Anatholy | |
| dc.date.accessioned | 2025-10-29T11:16:40Z | |
| dc.date.issued | 2016 | |
| dc.department | Fakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü | |
| dc.description.abstract | Greywater reuse is an attractive alternative to sustainable water management, especially in water scarcity situations. This study sought to determine the treatment efficiency of electrochemically produced ferrate(VI) in greywater, assessing ferrate(VI) dose requirements and pH effect. Greywater originating from a restaurant was employed in this research. The treatment efficiency was investigated with regard to the chemical oxygen demand (COD), total organic carbon, turbidity, surfactants, and anions removal. The optimum performance was achieved with 75mg/L of ferrate(VI) dose at pH 7. The settling characteristics of the treated greywater were also investigated. After treatment, larger particles and zeta potential values closer to zero were observed. Electrochemically produced ferrate(VI) showed promising performance for greywater treatment. | |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUBITAK) | |
| dc.description.sponsorship | The authors gratefully acknowledge the financial support of The Scientific and Technological Research Council of Turkey (TUBITAK), and Kate is thanked for skilful English revision. | |
| dc.identifier.doi | 10.1080/19443994.2015.1038740 | |
| dc.identifier.endpage | 11385 | |
| dc.identifier.issn | 1944-3994 | |
| dc.identifier.issn | 1944-3986 | |
| dc.identifier.issue | 24 | |
| dc.identifier.orcid | 0000-0003-3247-5337 | |
| dc.identifier.orcid | 0000-0003-4229-0408 | |
| dc.identifier.scopus | 2-s2.0-84959496157 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 11375 | |
| dc.identifier.uri | https://doi.org/10.1080/19443994.2015.1038740 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14854/7709 | |
| dc.identifier.volume | 57 | |
| dc.identifier.wos | WOS:000371252400040 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Desalination Publ | |
| dc.relation.ispartof | Desalination and Water Treatment | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20251020 | |
| dc.subject | Surfactant | |
| dc.subject | Zeta potential | |
| dc.subject | Oxidation | |
| dc.subject | Ferrate(VI) | |
| dc.subject | Particle size | |
| dc.subject | Coagulation | |
| dc.subject | Greywater | |
| dc.title | The treatment of greywater from a restaurant by electrosynthesized ferrate (VI) ion | |
| dc.type | Article |