A faulty feeder selection method for distribution network with unintentional resonance in zero sequence circuit

dc.contributor.authorAtsever, Mert Bekir
dc.contributor.authorHocaoglu, Mehmet Hakan
dc.date.accessioned2025-10-29T11:27:48Z
dc.date.issued2023
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractFaulty feeder selection is a challenging task for distribution system operator due to the low earth fault current magnitudes in compensated networks. However, extensive cable usage, especially in metropolitan cities, causes unintentional resonance in the network earthed through inductance or grounding transformer. The unintentionally resonated networks are not designed like intentionally compensated networks where faulty feeder should be isolated in a predetermined time. There are transient zero sequence current based methods, particularly synthesized for compensated networks to identify faulty feeders. However, zero sequence-based faulty feeder selection methods have drawbacks in the presence of underground cables. Further, transient zero sequence current is prone to many parameters such as capacitive imbalance and fault resistance. In this study, a transient negative sequence current based faulty feeder selection method is proposed. The effectiveness of the proposed method is demonstrated in a simulated 151-node distribution network. EMTP simulations are carried out by considering different fault inception times, fault resistance and capacitive imbalance of the system. Results show that negative sequence current offers selective faulty feeder selection and no false trip is observed in a representative unintentionally resonating distribution network.
dc.identifier.doi10.1016/j.epsr.2023.109587
dc.identifier.issn0378-7796
dc.identifier.issn1873-2046
dc.identifier.orcid0000-0003-2032-2261
dc.identifier.orcid0000-0001-6528-3812
dc.identifier.scopus2-s2.0-85164245097
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.epsr.2023.109587
dc.identifier.urihttps://hdl.handle.net/20.500.14854/10919
dc.identifier.volume223
dc.identifier.wosWOS:001029667000001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Sa
dc.relation.ispartofElectric Power Systems Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectCable
dc.subjectFalse trip
dc.subjectNegative sequence
dc.subjectTransient analysis
dc.titleA faulty feeder selection method for distribution network with unintentional resonance in zero sequence circuit