Dual enzymes-mimic activity of nanolayered manganese-calcium oxide for fluorometric determination of metformin

dc.contributor.authorRashtbari, Samaneh
dc.contributor.authorDehghan, Gholamreza
dc.contributor.authorKhataee, Simin
dc.contributor.authorAmini, Mojtaba
dc.contributor.authorKhataee, Alireza
dc.date.accessioned2025-10-29T11:29:50Z
dc.date.issued2022
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractThere are different analytical methods available for the determination of metformin, as an oral hypoglycemic and antidiabetic drug, in biological samples. However, most of these methods suffer from some drawbacks, including high-priced materials and equipment, damaging chemical reagents, time-consuming nature, and tedious operation procedures. So, in this work a new, sensitive and simple method was reported for the detection of metformine. In this regard, nanolayered manganese-calcium oxide (NL-MnCaO2) were synthesized and characterized using scanning electron microscopy (SEM), fourier transform infrared (FTIR) spectroscopy, and X-ray powder diffraction (XRD) techniques. Also, we studied the enzyme-like activity of synthesized particles and reported a bifunctional nanozyme, which performs the dual roles for peroxidase and catalase-mimicking. The results demonstrated the hindering effect of metformin on the peroxidase-mimic activity of NL-MnCaO2 and this effect was increased by raising metformin concentration. So, a sensitive fluorometric detection system was designed for the analytical assay of metformin, based on the terephthalic acid (TA)-H2O2 reaction with NL-MnCaO2. An acceptable linearity was observed between the metformin concentration and fluorescence quenching of the system in the range of 0.07-0.77 mM. Limit of detection (LOD) and limit of quantification (LOQ) were 0.17 mu M and 0.96 mu M, respectively. The proposed system was applied for the estimation of metformin concentration in serum samples by recoveries of 86.68-106%. So, the proposed fluorometric method provides some main advantages such as wide linear range, low detection limit, rapid detections, high sensitivity, and good practicability for the determination of metformin in biological samples.
dc.identifier.doi10.1016/j.chemosphere.2021.133063
dc.identifier.issn0045-6535
dc.identifier.issn1879-1298
dc.identifier.orcid0000-0001-6509-5942
dc.identifier.orcid0000-0002-7813-5226
dc.identifier.orcid0009-0001-7078-829X
dc.identifier.orcid0000-0002-0912-5470
dc.identifier.pmid34848228
dc.identifier.scopus2-s2.0-85120643707
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.chemosphere.2021.133063
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11293
dc.identifier.volume291
dc.identifier.wosWOS:000757893900003
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofChemosphere
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectMetformin
dc.subjectFluorometric method
dc.subjectManganese-calcium oxide
dc.subjectDual-enzyme mimetic activity
dc.titleDual enzymes-mimic activity of nanolayered manganese-calcium oxide for fluorometric determination of metformin
dc.typeArticle

Dosyalar