Process optimization for Cr(VI) adsorption onto activated carbons by experimental design

dc.contributor.authorÖzdemir, Ercan
dc.contributor.authorDuranoglu, Dilek
dc.contributor.authorBeker, Ulker
dc.contributor.authorAvci, Asli Ozge
dc.date.accessioned2025-10-29T11:30:03Z
dc.date.issued2011
dc.departmentFakülteler, Mühendislik Fakültesi, Kimya Mühendsisliği Bölümü
dc.description.abstractA study on the adsorption of Cr(VI) onto raw and modified activated carbons was conducted and the process parameters were optimized using Response Surface Methodology (RSM). Apricot stones have been converted to microporous activated carbon with considerably high surface area (1462 m(2) g(-1)) by phosphoric acid activation. Produced carbons have been characterized by using different physicochemical methods. In order to determine the effects of process parameters namely temperature (20-60 degrees C), initial solution pH (2-6) and initial Cr(VI) concentration (30-60 mg L-1) on Cr(VI) uptake from aqueous solution, a three-level, three-factor, Box-Behnken design has been employed. The second order mathematical model was developed by regression analysis of the experimental data obtained from 17 batch runs. The optimum pH, temperature and initial concentration were found to be 2.0, 60 degrees C, and 60 mg L. respectively. Cr(VI) adsorption capacity was 262 mg g(-1) at the optimum combination of process parameters. The enthalpy change of Cr(VI) adsorption was found to be 54.05 kJ mol(-1). Dynamic adsorption data were applied to pseudo-first-order and pseudo-second-order rate equations. Pseudo-second-order kinetic model well expressed Cr(VI) adsorption onto activated carbon. The results of both thermodynamic and kinetic study indicated the chemical interaction between Cr(VI) species and surface functional groups on carbon surface. (C) 2011 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.cej.2011.05.091
dc.identifier.endpage218
dc.identifier.issn1385-8947
dc.identifier.issn1873-3212
dc.identifier.issue1
dc.identifier.orcid0000-0003-4037-7163
dc.identifier.scopus2-s2.0-79960972735
dc.identifier.scopusqualityQ1
dc.identifier.startpage207
dc.identifier.urihttps://doi.org/10.1016/j.cej.2011.05.091
dc.identifier.urihttps://hdl.handle.net/20.500.14854/11395
dc.identifier.volume172
dc.identifier.wosWOS:000295438800024
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Sa
dc.relation.ispartofChemical Engineering Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectChromium removal
dc.subjectActivated carbon
dc.subjectBox-Behnken Response Surface
dc.subjectMethodology
dc.subjectExperimental design
dc.subjectProcess optimization
dc.titleProcess optimization for Cr(VI) adsorption onto activated carbons by experimental design
dc.typeArticle

Dosyalar