Nonlinear finite element modelling of centric dowel connections in precast buildings

dc.contributor.authorZoubek, Blaz
dc.contributor.authorFahjan, Yasin
dc.contributor.authorFischinger, Matej
dc.contributor.authorIsakovic, Tatjana
dc.date.accessioned2025-10-29T11:12:29Z
dc.date.issued2014
dc.departmentGebze Teknik Üniversitesi
dc.description.abstractThe modelling approach in the case of connections in precast buildings is specific. The assembly of the constitutive parts of the connection requires the inclusion of contact definitions in the model. In addition, the material non-linearity including the influence of the spatial stress distribution should be taken into account where appropriate. Here a complex model of a beam-to-column dowel connection is presented. Experiments on the analysed connection were performed within the framework of the European project SAFECAST (Performance of Innovative Mechanical Connections in Precast Building Structures under Seismic Conditions). Several material and interaction parameters were investigated and the influence of each of them was evaluated. The set of parameters which gave the best match with the experiments was chosen.
dc.description.sponsorshipEuropean Commission [218417-2]
dc.description.sponsorshipThe presented research was supported by the SAFECAST project Performance of Innovative Mechanical Connections in Precast Building Structures under Seismic Conditions (Grant agreement no. 218417-2) in the framework of the Seventh Framework Programme (FP7) of the European Commission. The experiments were completed at the Slovenian National Building and Civil Engineering Institute (ZAG). The specimens were constructed at the Primorje d.d. company.
dc.identifier.doi10.12989/cac.2014.14.4.463
dc.identifier.endpage477
dc.identifier.issn1598-8198
dc.identifier.issn1598-818X
dc.identifier.issue4
dc.identifier.orcid0000-0003-1254-4526
dc.identifier.scopus2-s2.0-84908459953
dc.identifier.scopusqualityQ1
dc.identifier.startpage463
dc.identifier.urihttps://doi.org/10.12989/cac.2014.14.4.463
dc.identifier.urihttps://hdl.handle.net/20.500.14854/6312
dc.identifier.volume14
dc.identifier.wosWOS:000344578000006
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTechno-Press
dc.relation.ispartofComputers and Concrete
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectdowel connection
dc.subjectprecast buildings
dc.subjectconcrete modelling
dc.subjectCDP model
dc.subjectinteraction modelling
dc.subjectfailure mechanism
dc.subjectfailure analysis
dc.titleNonlinear finite element modelling of centric dowel connections in precast buildings
dc.typeArticle

Dosyalar