Analysis of Surface Properties of Ag and Ti Ion-Treated Medical Textiles by Metal Vapor Vacuum Arc Ion Implantation

dc.contributor.authorAkpek, Ali
dc.date.accessioned2025-10-29T11:08:59Z
dc.date.issued2021
dc.departmentFakülteler, Mühendislik Fakültesi, Biyomühendislik Bölümü
dc.description.abstractThe study focuses on the effects of Ag (silver) and Ti (titanium) ions on textiles by MEVVA (metal vapor vacuum arc) ion implantation. In order to comprehend this, the research was executed in three parts. In the first part, the antibacterial efficiencies of Ag and TiO2 were investigated in detail since the antibacterial capabilities of Ag and TiO2 are well known. A group of polyester- and cotton-based medical textiles were modified by Ag and TiO2 ions, with doses ranging from 5 x 10(15) to 5 x 10(16) ion/cm(2). To determine the adhesion capabilities of the implanted ions on surfaces, after the first round of antibacterial tests, these medical textiles were washed 30 times, and then antibacterial tests were performed for the second time. The results were also compared with nanoparticle-treated medical textiles. In the second part, the corrosion and friction capabilities of Ag and Ti ion-implanted polyester textiles, with a dose of 5 x 10(15) ion/cm(2), were investigated. Finally, the UV protection capabilities of Ag and Ti ion-implanted polyester textiles, with a dose of 5 x 10(15) ion/cm(2), were investigated. The experiments showed that even after 30 washes, the TiO2 ion-implanted polyester textile had almost 85% antibacterial efficiency. In addition, Ti ion implantation reduced the friction coefficiency of a polyester textile by almost 50% when compared with an untreated textile. Finally, the Ag-ion-implanted polyester textile provided a UV protection factor of 30, which is classified as very good protection.
dc.identifier.doi10.3390/coatings11010102
dc.identifier.issn2079-6412
dc.identifier.issue1
dc.identifier.orcid0000-0003-2803-6585
dc.identifier.scopus2-s2.0-85099865521
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.3390/coatings11010102
dc.identifier.urihttps://hdl.handle.net/20.500.14854/5617
dc.identifier.volume11
dc.identifier.wosWOS:000610972200001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorAkpek, Ali
dc.language.isoen
dc.publisherMdpi
dc.relation.ispartofCoatings
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20251020
dc.subjectsurface engineering
dc.subjection implantation
dc.subjectMEVVA
dc.subjectantibacterial
dc.subjectcorrosion
dc.subjectUV protection
dc.titleAnalysis of Surface Properties of Ag and Ti Ion-Treated Medical Textiles by Metal Vapor Vacuum Arc Ion Implantation
dc.typeArticle

Dosyalar