Comparison of the performance characteristics of the tonpilz transducers fabricated from 0.60PMN-0.40PT & PZT piezoceramics

dc.contributor.authorYalcin, Ezgi
dc.contributor.authorAnkut, Merve
dc.contributor.authorSungur, Sena M.
dc.contributor.authorTurgut, H. Ibrahim
dc.contributor.authorKar, K. Sueda
dc.contributor.authorAlkoy, Sedat
dc.contributor.authorAykac, Aykut
dc.date.accessioned2025-10-29T11:19:19Z
dc.date.issued2021
dc.departmentFakülteler, Temel Bilimler Fakültesi, Matematik Bölümü
dc.departmentFakülteler, Mühendislik Fakültesi, Malzeme Bilimi ve Mühendisliği Bölümü
dc.description.abstractIn this study, tonpilz transducers based on 0.60Pb(Mg1/3Nb2/3)O-3-0.40PbTiO(3) (60PMN-PT) and commercially available lead zirconate titanate (PZT) compositions (PZT 4, PZT 5H, PZT 8 and PZT 5A) were designed, fabricated, characterized and compared for their underwater performance. Each stack is composed of two rings of PZT or PMN-PT ceramics. Transducers were designed and analyzed using the commercial ATILA finite elements analysis (FEA) code. Commercially available powders were used for PZT, whereas 60PMN-PT powders with pure perovskite phase were synthesized using solid-state reaction route. Ceramic rings have been produced using dry pressing. Dielectric, piezoelectric and electromechanical properties of the rings were calculated using the resonance method. Vibration modes of the rings and transducers constructed from various types of piezoceramics were analyzed using FEA. The main resonance frequency of the tonpilz transducer belonging to the longitudinal piston mode was measured in the mid-frequency range between 30 and 35 kHz. Underwater acoustic measurements were conducted on polymer-coated transducers, and their performances were compared for possible underwater acoustic applications. Transducers fabricated from 60PMN-PT were found to have comparable underwater performance with that of PZT 4, where the Transmitting Voltage Response (TVR) reached 135 - 136 dB re 1 mu Pa/V @1 m range with a -3dB bandwidth of 4 kHz. These results indicated the viability of using 60PMN-PT ceramics in active device applications in an array form.
dc.identifier.doi10.1080/00150193.2021.2014261
dc.identifier.endpage92
dc.identifier.issn0015-0193
dc.identifier.issn1563-5112
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85124235903
dc.identifier.scopusqualityQ4
dc.identifier.startpage82
dc.identifier.urihttps://doi.org/10.1080/00150193.2021.2014261
dc.identifier.urihttps://hdl.handle.net/20.500.14854/8105
dc.identifier.volume586
dc.identifier.wosWOS:000751809900002
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTaylor & Francis Ltd
dc.relation.ispartofFerroelectrics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectPiezoelectricity
dc.subjecttonpilz transducer
dc.subjectPMN-PT
dc.subjectPZT
dc.subjectFEA
dc.titleComparison of the performance characteristics of the tonpilz transducers fabricated from 0.60PMN-0.40PT & PZT piezoceramics
dc.typeArticle