Operating cost and treatment of metalworking fluid wastewater by chemical coagulation and electrocoagulation processes

Yükleniyor...
Küçük Resim

Tarih

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Inst Chemical Engineers

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The present study dealt with treatment performances and operating cost of real metalworking fluid wastewater (MWFW) using chemical coagulation (CC) and electrocoagulation (EC) processes. The optimum coagulant dosage for COD and TOC removal efficiencies from the MWFW was determined with varying concentrations of alum, aluminium chloride, ferric sulphate, and ferric chloride. COD and TOC removal efficiencies in the coagulant dosage range of 50-1000 mg/L were obtained as 65-97% and 49-81% for alum, 48-96% and 38-80% for aluminium chloride, 43-92% and 36-76% for ferric sulphate, and 55-93% and 41-77% for ferric chloride, respectively. The aluminium-based coagulants at a pH of 7.5 showed better performances than ferric-based coagulants in terms of COD and TOC removals. COD and TOC removal efficiencies from the MWFW in the EC process were 93% and 80% for Al electrode at a pH of 5, 80 A/m(2) and 25 min, and 93% and 82% for Fe electrode at a pH of 7, 80 A/m(2) and 25 min, respectively. Operating costs at the optimum conditions were calculated to be 1.190 US $/m(3) for Al and 1.813 US $/m(3) for Fe electrodes, respectively. Alum in chemical coagulation process provided a lower operating cost (0.12 US $/m(3)) as compared with the EC process using Al electrode (1.19 US $/m(3)). The results demonstrated that both investigated treatment processes were effective to treat wastewater from a metalworking plant. (C) 2016 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.

Açıklama

Anahtar Kelimeler

Metalworking fluid wastewater, Coagulation, Electrocoagulation, Operating cost, Iron electrode, Aluminium electrode

Kaynak

Process Safety and Environmental Protection

WoS Q Değeri

Scopus Q Değeri

Cilt

105

Sayı

Künye

Onay

İnceleme

Ekleyen

Referans Veren