Operating cost and treatment of metalworking fluid wastewater by chemical coagulation and electrocoagulation processes

dc.contributor.authorDemirbas, E.
dc.contributor.authorKobya, M.
dc.date.accessioned2025-10-29T11:23:30Z
dc.date.issued2017
dc.departmentFakülteler, Temel Bilimler Fakültesi, Kimya Bölümü
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractThe present study dealt with treatment performances and operating cost of real metalworking fluid wastewater (MWFW) using chemical coagulation (CC) and electrocoagulation (EC) processes. The optimum coagulant dosage for COD and TOC removal efficiencies from the MWFW was determined with varying concentrations of alum, aluminium chloride, ferric sulphate, and ferric chloride. COD and TOC removal efficiencies in the coagulant dosage range of 50-1000 mg/L were obtained as 65-97% and 49-81% for alum, 48-96% and 38-80% for aluminium chloride, 43-92% and 36-76% for ferric sulphate, and 55-93% and 41-77% for ferric chloride, respectively. The aluminium-based coagulants at a pH of 7.5 showed better performances than ferric-based coagulants in terms of COD and TOC removals. COD and TOC removal efficiencies from the MWFW in the EC process were 93% and 80% for Al electrode at a pH of 5, 80 A/m(2) and 25 min, and 93% and 82% for Fe electrode at a pH of 7, 80 A/m(2) and 25 min, respectively. Operating costs at the optimum conditions were calculated to be 1.190 US $/m(3) for Al and 1.813 US $/m(3) for Fe electrodes, respectively. Alum in chemical coagulation process provided a lower operating cost (0.12 US $/m(3)) as compared with the EC process using Al electrode (1.19 US $/m(3)). The results demonstrated that both investigated treatment processes were effective to treat wastewater from a metalworking plant. (C) 2016 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.psep.2016.10.013
dc.identifier.endpage90
dc.identifier.issn0957-5820
dc.identifier.issn1744-3598
dc.identifier.orcid0000-0001-5052-7220
dc.identifier.orcid0000-0001-6732-8893
dc.identifier.scopus2-s2.0-84994008719
dc.identifier.scopusqualityQ1
dc.identifier.startpage79
dc.identifier.urihttps://doi.org/10.1016/j.psep.2016.10.013
dc.identifier.urihttps://hdl.handle.net/20.500.14854/9481
dc.identifier.volume105
dc.identifier.wosWOS:000392789200009
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherInst Chemical Engineers
dc.relation.ispartofProcess Safety and Environmental Protection
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20251020
dc.subjectMetalworking fluid wastewater
dc.subjectCoagulation
dc.subjectElectrocoagulation
dc.subjectOperating cost
dc.subjectIron electrode
dc.subjectAluminium electrode
dc.titleOperating cost and treatment of metalworking fluid wastewater by chemical coagulation and electrocoagulation processes
dc.typeArticle